Duct Type VRF Air Conditioner Indoor Unit

Low ESP Duct Type VRF Indoor Unit

Low ESP duct type VRF indoor unit

- Capacity from 2.2kw to 7.1kw

- Slim body with 181mm thickness, 220mm height ceiling is required.

- 220V/1Ph/50Hz, 220V/1Ph/60Hz

- Plenum box optional

- Bottom or rear air return optional.

Model name Power type Capacity Motor input  Air flow Sound Level ESP Dimension (W×H×D) Weight Connecting pipe Standard controller
Cooling Heating Packing Body packing Panel Net Gross Gas Liquid Drain
kW kBtu/h kW kBtu/h kW m3/h CFM dB(A) Pa mm mm mm mm kg kg mm mm mm
CMV-V22TA/HR1-B 50Hz 2.2 7.5 2.5 8.5 0.045 450 260 2936 20 1055×250×605 925×181×510 / / 17 20 Ø9.53 Ø6.35 Ø20 Wired controller
CMV-V22TA/HNR1-B 60Hz
CMV-V28TA/HR1-B 50Hz 2.8 9.5 3.2 10.9 17 20
CMV-V28TA/HNR1-B 60Hz
CMV-V32TA/HR1-B 50Hz 3.2 10.9 3.5 11.9 0.065 550 320 3037 17.5 20.5 Ø12.7
CMV-V32TA/HNR1-B 60Hz
CMV-V36TA/HR1-B 50Hz 3.6 12.2 4 13.6 17.5 20.5
CMV-V36TA/HNR1-B 60Hz
CMV-V45TA/HR1-B 50Hz 4.5 15.3 5 17 0.075 780 450 3240 1330×250×605 1205×181×510 21 25
CMV-V45TA/HNR1-B 60Hz
CMV-V56TA/HR1-B 50Hz 5.6 19.1 6.3 21.4 21 25
CMV-V56TA/HNR1-B 60Hz
CMV-V71TA/HR1-B 50Hz 7.1 24.2 8 27.2 0.105 1100 640 3542 1645×250×605 1530×181×510 26 30 Ø15.9 Ø9.53
CMV-V71TA/HNR1-B 60Hz

Short Body Duct Type VRF Indoor Unit

Short body duct type VRF, VRV indoor unit

- Capacity from 2.2kw to 7.1kw

- Short body, minimum 700mm width.

- 220V/1Ph/50Hz, 220V/1Ph/60Hz

- With standard plenum boxl

- Bottom or rear air return optional.

- Built-in drain pump, head 750mm

Model name Power type Capacity Motor input  Air flow Sound Level ESP Dimension (W×H×D) Weight Connecting pipe Standard controller
Cooling Heating Packing Body packing Panel Net Gross Gas Liquid Drain
kW kBtu/h kW kBtu/h kW m3/h CFM dB(A) Pa mm mm mm mm kg kg mm mm mm
CMV-V22TA/HR1-C 50Hz 2.2 7.5 2.5 8.5 0.05 450 260 2429 30 900×240×530 700×210×467 / / 16 19 Ø9.53 Ø6.35 External Diameter  Ø25 Wired controller
CMV-V22TA/HNR1-C 60Hz
CMV-V28TA/HR1-C 50Hz 2.8 9.5 3.2 10.9 16 19
CMV-V28TA/HNR1-C 60Hz
CMV-V36TA/HR1-C 50Hz 3.6 12.2 4 13.6 0.07 550 324 2532 16 19 Ø12.7
CMV-V36TA/HNR1-C 60Hz
CMV-V45TA/HR1-C 50Hz 4.5 15.3 5 17 0.08 620 360 3338 16 19
CMV-V45TA/HNR1-C 60Hz
CMV-V56TA/HR1-C 50Hz 5.6 19.1 6.3 21.4 0.09 900 520 2738 1110×240×530 900×210×467 19 22.5
CMV-V56TA/HNR1-C 60Hz
CMV-V71TA/HR1-C 50Hz 7.1 24.2 8 27.2 0.11 1100 640 2939 1310×240×530 1100×210×467 22 26 Ø15.9 Ø9.53
CMV-V71TA/HNR1-C 60Hz

Medium ESP Duct Type VRF Indoor Unit

Medium ESP Duct Type VRF Indoor Unit

- Capacity from 7.1kw to 15kw

- Whole unit low noise design, silent operation

- 220V/1Ph/50Hz, 220V/1Ph/60Hz

- Standard with plenum box

- Bottom or rear air return optional.

Model name Power type Capacity Motor input  Air flow Sound Level ESP Dimension (W×H×D) Weight Connecting pipe Standard controller
Cooling Heating Packing Body packing Panel Net Gross Gas Liquid Drain
kW kBtu/h kW kBtu/h kW m3/h CFM dB(A) Pa mm mm mm mm kg kg mm mm mm
CMV-V71TB/HR1-B 50Hz 7.1 24.2 8.0 27.2 0.30 1220 710 3641 70 1245×320×720 1209×260×680 / / 33 37 Ø15.9 Ø9.53 Ø25 Wired controller
CMV-V71TB/HNR1-B 60Hz
CMV-V80TB/HR1-B 50Hz 8.0 27.2 9.0 30.7 33 37
CMV-V80TB/HNR1-B 60Hz
CMV-V90TB/HR1-B 50Hz 9.0 30.7 10.0 34.1 0.34 1850 1080 3843 1480×320×720 1445×260×680 46 50 Ø19.1
CMV-V90TB/HNR1-B 60Hz
CMV-V100TB/HR1-B 50Hz 10.0 34.1 11.0 37.5 2000 1170 4044 46 50
CMV-V100TB/HNR1-B 60Hz
CMV-V120TB/HR1-B 50Hz 12.0 40.9 13.0 44.3 46 50
CMV-V120TB/HNR1-B 60Hz
CMV-V150TB/HR1-B 50Hz 15.0 51.1 17.0 58 46 50
CMV-V150TB/HNR1-B 60Hz

High ESP Duct Type VRF Indoor Unit

Medium ESP Duct Type VRF,VRV Indoor Unit

- Capacity from 7.1kw to 56kw

- Slim body, saving suspended ceiling space

- 220V/1Ph/50Hz, 220V/1Ph/60Hz

- Standard with plenum box

- Rear air return optional.

Model name Power type Capacity Motor input  Air flow Sound Level ESP Dimension (W×H×D) Weight Connecting pipe Standard controller
Cooling Heating Packing Body packing Panel Net Gross Gas Liquid Drain
kW kBtu/h kW kBtu/h kW m3/h CFM dB(A) Pa mm mm mm mm kg kg mm mm mm
CMV-V71TH/HR1-B 50Hz 7.1 24.2 7.8 26.6 0.34 1500 880 4042 150 1480×320×720 1445×260×680 / / 46 50 Ø15.9 Ø9.53 Ø25 Wired controller
CMV-V71TH/HNR1-B 60Hz
CMV-V80TH/HR1-B 50Hz 8.0 27.2 8.8 30 4042 46 50
CMV-V80TH/HNR1-B 60Hz
CMV-V90TH/HR1-B 50Hz 9.0 30.7 10.0 34.1 4042 46 50 Ø19.1
CMV-V90TH/HNR1-B 60Hz
CMV-V100TH/HR1-B 50Hz 10.0 34.1 11.0 37.5 0.45 2300 1350 4452 1245×445×655 1190×370×620 47 51
CMV-V100TH/HNR1-B 60Hz
CMV-V120TH/HR1-B 50Hz 12.0 40.9 13.0 44.3 47 51
CMV-V120TH/HNR1-B 60Hz
CMV-V150TH/HR1-B 50Hz 15.0 51.1 17.0 58 4452 47 51
CMV-V150TH/HNR1-B 60Hz
CMV-V200TH/HR1-B 50Hz 20.0 68.2 22 75 1.20 4000 2350 45~53 1510×490×870 1465×448×811 102 106 Ø12.7 Ø22
CMV-V200TH/HNR1-B 60Hz
CMV-V250TH/HR1-B 50Hz 25 85.3 27.5 93.8 1.20 4200 2470 45~54 102 106
CMV-V250TH/HNR1-B 60Hz
CMV-V280TH/HR1-B 50Hz 28 95.5 30.8 105 1.20 4400 2580 45~55 102 106
CMV-V280TH/HNR1-B 60Hz

Notes:

1. Power supply: 220~240V/1PH for 50Hz; 208~230V/1PH for 60Hz

2. Cooling test condition: indoor side 27°C DB, 19°C WB outdoor side 35°C DB. Heating test condition: indoor side 20°C DB, 15°C WB outdoor side 7°C DB

3. Sound level: measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

4. The above data may be changed without notice for future improvement on quality and performance.