Universal Fan Coil Unit

Ceiling Floor Fan Coil Unit

Available in exposure installation and concealed installation.

Capacity: 1.8kw-12.6kw

Air flor volume: 200CFM-1400CFM

Power supply: 220V/1Ph/50Hz

This unit can be installed vertically or horizontally

Left/right water pipe connection can be selected.

2-tube system and 4-tube system available for selection

Six modes of air flowing for selection. 

Universal fan coil unit

 Available with concealed model

Universal concealed fan coil unit

Specification (2-tube system)

model CSU-200TM CSU-300TM CSU-400TM CSU-500TM CSU-600TM CSU-800TM CSU-1000TM CSU-1200TM CSU-1400TM
CSU-200TA CSU-300TA CSU-400TA CSU-500TA CSU-600TA CSU-800TA CSU-1000TA CSU-1200TA CSU-1400TA
power supply 220V,50Hz,1Ph
air volume H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M 260 390 510 640 770 1020 1280 1530 1790
L 170 260 340 430 510 680 850 1020 1190
H CFM 200 300 400 500 600 800 1000 1200 1400
M 153 229 300 376 453 600 753 900 1053
L 100 153 200 253 300 400 500 600 700
cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
BTU/h 6142 9212 12283 15354 18425 24566 30708 36850 42991
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
BTU/h 4668 7001 9335 11669 13999 18667 23335 28002 32670
TH M W 1494 2242 2989 3736 4483 5978 7472 8967 10461
SH W 1181 1771 2362 2952 3541 4722 5903 7084 8265
TH L W 1162 1744 2325 2906 3487 4649 5812 6974 8136
SH W 953 1430 1907 2383 2860 3813 4765 5718 6672
heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M W 2131 3197 4262 5328 6393 8524 10655 12786 14917
L W 1675 2511 3349 4186 5024 6697 8372 10046 11721
noise H 0Pa dB(A) 37 39 41 43 45 46 48 50 51
power input H 0Pa W 37 52 62 76 96 134 152 189 228
waterflow volume   m3/h 0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85 2.16
water pressure dropping kPa 7 15 18 23 28 30 22 30 36
dimension of water(in & out)connection pipe in ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
out ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
Maximum working pressure Mpa 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Condensation pipe size(diameter) mm ∅21
 

Specification (4-tube system)

model CSU-200TM4 CSU-300TM4 CSU-400TM4 CSU-500TM4 CSU-600TM4 CSU-800TM4 CSU-1000TM4 CSU-1200TM4 CSU-1400TM4
CSU-200TA4 CSU-300TA4 CSU-400TA4 CSU-500TA4 CSU-600TA4 CSU-800TA4 CSU-1000TA4 CSU-1200TA4 CSU-1400TA4
power supply 220V,50Hz,1Ph
air volume H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M 260 390 510 640 770 1020 1280 1530 1790
L 170 260 340 430 510 680 850 1020 1190
H CFM 200 300 400 500 600 800 1000 1200 1400
M 153 229 300 376 453 600 753 900 1053
L 100 153 200 253 300 400 500 600 700
cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
BTU/h 6142 9212 12283 15354 18425 24566 30708 36850 42991
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
BTU/h 4668 7001 9335 11669 13999 18667 23335 28002 32670
TH M W 1494 2242 2989 3736 4483 5978 7472 8967 10461
SH W 1181 1771 2362 2952 3541 4722 5903 7084 8265
TH L W 1162 1744 2325 2906 3487 4649 5812 6974 8136
SH W 953 1430 1907 2383 2860 3813 4765 5718 6672
heating capacity H W 1300 1940 2590 3240 3890 5180 6480 7780 9070
M W 1020 1530 2040 2550 3060 4070 5090 6110 7130
L W 820 1230 1630 2040 2450 3270 4080 4900 5720
noise H 0Pa dB(A) 37 39 41 43 45 46 48 50 51
power input H 0Pa W 37 52 62 76 96 134 152 189 228
waterflow volume Cooling m3/h 0.31 0.46 0.62 0.77 0.93 1.23 1.54 1.85 2.16
waterflow volume heating 0.11 0.17 0.22 0.28 0.34 0.45 0.56 0.67 0.78
water pressure dropping cooling  kPa 7 15 18 23 28 30 22 30 36
heating 2.8 6 7.2 9.2 11.2 12 8.8 12 14.4
dimension of water(in & out)connection pipe cooling/heating ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
ZG1/2" ZG1/2" ZG1/2" ZG1/2" ZG1/2" ZG1/2" ZG1/2" ZG1/2" ZG1/2"
coil type high efficient copper pipe to wear Hydrophilic aluminum coil
Maximum working pressure Mpa 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Condensation pipe size(diameter) mm ∅21

Note:

1) Cooling condition: ambient temperature DB/WB 27℃/19.5℃,chilled water input/output temp.:7℃/12℃;

2) Heating condition:ambient temperature DB 20℃, hot water input/output temp.:60℃/50℃;

3) Above data are subject to change without prior notice.